ESP Design
ESP Logo

ESP Professional Design & Analysis System

Well Information
⚠️ Use Vertical Depth (VD) for all calculations, not Measured Depth (MD)
Detailed Fluid Properties
Fresh water: 1.0, Brine: 1.02-1.15
Typical range: 0.6-0.9 for natural gas
Range: 0-20%, Typical: 3-12%
Range: 0-30%, Typical: 0-5%
Typical: 3-7%, Corrosive if >10%
⚠️ Sour if >0.5%, Requires special materials
Typical: 0.5-3%, Inert component
Production & Fluid Parameters
💡 Free Gas depends on PIP < Pb (pressure below bubble point)
💡 Critical for gas calculations: PIP < Pb → free gas
Production Tubing Configuration
Standard Tubing Configuration
Section 1: 2-7/8" from ESP to Packer (9.5m joints)
Section 2: 3-1/2" from Packer to transition point
Section 3: 4-1/2" from transition to Wellhead
💡 System automatically calculates weighted average ID for friction loss
ID: 2.441" | Length: 104.5m (ESP to Packer)
ID: 2.992" | Length: 798m (Middle section)
ID: 3.958" | Length: 598.5m (Upper to wellhead)
✓ Auto-calculated from joint counts
✓ Used for friction loss calculation
Well Geometry & Configuration
Vertical Depth (not MD)
💡 Production zone starts here
ℹ️ Vertical Depth (VD) - See recommended depth below
⚠️ If packer installed: Gas Separator NOT possible (use Gas Handler)
Pressure Analysis at Pump Intake
💡 PIP = Pr - 0.433 × SG_comp × (Datum - Pump_Depth). Use SG_comp (Mass-based)
📊 Enter value from Monitoring tab after ESP is running (if sensor installed).
ℹ️ System will use the minimum pressure for safe design.
⚠️ Typical: 430 psi (~3.0 MPa) | Alert triggers if actual drawdown exceeds this limit
Equipment Selection & Comparison
Select primary electrical supply configuration

Calculate ESP Design First

Equipment selection and comparison will appear here after calculation

Data Management
💾 Save all input values to a JSON file for backup or sharing
📁 Load previously saved input values from JSON file
⚡ Quick access: Use the Calculate button in the header above
Pump Performance Curves
Multi-Frequency Analysis
Cable Voltage Drop Analysis
Temperature Coefficient Analysis
Equipment Comparison Tool
ESP Equipment Database
0 items
Monitoring Configuration
Monitoring Data Log
Analytics Summary
Multi-Parameter Trend Analysis (Click legend to show/hide parameters • Static readings excluded from chart)
Generate Reports & Export Data

Report Preview

Complete a design calculation to generate report

Configuration
Pump Defaults
Used when pump efficiency is 0 or invalid (0-1 decimal)
Used when head/stage is 0 or missing
Used when max stages is 0 or invalid
Multiplier for calculated stages (1.15 = 15% margin)
Used if BHP calculation results in Infinity/NaN
Motor & Seal Defaults
Used when seal HP is invalid
Used when motor efficiency is missing (0-1 decimal)
Gas Separator Defaults
Used when gas separator efficiency is missing
Cable & Tubing Defaults
Fallback cable size if selection fails
Cable length from wellhead to control panel (default: 120m)
Hazen-Williams coefficient (120 = new tubing)
Results